ISO 12721:2000
Non-destructive testing — Thermal neutron radiographic testing — Determination of beam L/D ratio
| Fecha edición: |
2000-04-06
En Vigor
|
|---|---|
| Idiomas disponibles: | Inglés, Francés |
| Resumen: | This International Standard defines an empirical technique for the measurement of the effective collimation ratio and effective L/D of thermal neutron radiography beams for values between 20 and 1 000. The technique is based upon analysis of a neutron radiographic image and is independent of measurements and calculations based on physical dimensions of the collimator system. The device described in this International Standard has been developed and tested using Gd foil converters with a single emulsion, high resolution film in vacuum cassettes. La présente Norme internationale spécifie une méthode empirique permettant de mesurer le rapport efficace de collimation (L/D efficace) des faisceaux de neutrons thermiques utilisés en neutronographie, pour des valeurs comprises entre 20 et 1000. Cette technique est basée sur l'analyse d'une image obtenue par neutronographie thermique et ne dépend pas des mesurages et des calculs fondés sur les dimensions physiques du collimateur. Le dispositif décrit dans la présente Norme internationale a été élaboré et soumis à essai en utilisant, dans des cassettes à vide, des convertisseurs à feuilles de gadolinium avec un film haute résolution, émulsionné d'un seul côté. |
| ICS: | 19.100 - Ensayos no destructivos |
| CTN: | ISO/TC 135/SC 5 - 52418 |