IEC 60076-3:2013

Power transformers - Part 3: Insulation levels, dielectric tests and external clearances in air

Edition date: 2013-07-31
In Force
Available languages: Spanish, English, French
Summary: IEC 60076-3:2013 specifies the insulation requirements and the corresponding insulation tests with reference to specific windings and their terminals. This International Standard applies to power transformers as defined by IEC 60076-1. It also recommends external clearances in air. It gives details of the applicable dielectric tests and minimum dielectric test levels. Recommended minimum external clearances in air between live parts and between live parts and earth are given for use when these clearances are not specified by the purchaser. For categories of power transformers and reactors which have their own IEC standards, this standard is applicable only to the extent in which it is specifically called up by cross reference in the other standards. This third edition of IEC 60076-3 cancels and replaces the second edition published in 2000, and constitutes a technical revision. The main changes from the previous edition are as follows:
- Three categories of transformer are clearly identified together with the relevant test requirements, these are summarised in Table 1.
- Switching impulse levels are defined for values of Um > 72,5 kV.
- The procedure for Induced voltage tests with PD has been revised to ensure adequate phase to phase test voltages.
- The AC withstand test has been redefined (LTAC instead of ACSD).
- Induced voltage tests are now based on Ur rather than Um. - New requirements for impulse waveshape (k factor) have been introduced.
- Tables of test levels have been merged and aligned with IEC 60071-1:2010.
- Additional test levels have been introduced for Um > 800 kV.
- A new Annex E has been introduced, which sets out the principles used in assigning the tests, test levels and clearances in air.

La CEI 60076-3:2013 spécifie les exigences d'isolement et d'essais diélectriques correspondants en faisant référence aux enroulements spécifiques et à leurs bornes. La présente Norme internationale s'applique aux transformateurs de puissance définis dans le domaine d'application de la CEI 60076-1. Elle recommande également les distances d'isolement dans l'air. Elle fournit les détails des essais diélectriques et des niveaux d'essai diélectriques minimum applicables. Des distances d'isolement dans l'air minimales recommandées entre les parties sous tension et entre ces dernières et la terre sont précisées pour être utilisées lorsque ces distances dans l'air ne sont pas spécifiées par l'acheteur. Pour les catégories de transformateurs de puissance et de bobines d'inductance qui disposent d'une norme CEI qui leur est propre, la présente norme est applicable uniquement dans la mesure où il y est fait explicitement référence dans les autres normes. Cette troisième édition de la CEI 60076-3 annule et remplace la deuxième édition parue en 2000, dont elle constitue une révision technique. Les modifications principales par rapport à l'édition antérieure sont les suivantes:
- Trois catégories de transformateurs sont clairement identifiées ainsi que les exigences d'essais correspondantes, elles sont résumées dans le Tableau 1.
- Les niveaux de tenue au choc de manoeuvre sont définis pour toutes les valeurs de Um > 72,5 kV.
- La procédure d'essais de tension induite avec PD a été révisée pour garantir des tensions d'essais entre phase adéquates.
- L'essai de tenue en tension alternative a été redéfini (LTAC à la place de ACSD).
- Les niveaux d'essais de tenue en tension induite sont à présent fondés sur Ur plutôt que sur Um.
- De nouvelles exigences relatives à la forme de l'onde de choc (facteur k) ont été introduites.
- Les tableaux des niveaux d'essai ont été fusionnés et leurs valeurs alignés sur celles de la CEI 60071-1:2010.
- Des niveaux d'essai supplémentaires ont été introduits pour Um > 800 kV.
- Une nouvelle Annexe E a été introduite, qui fixe certains des principes utilisés pour le choix des essais, des niveaux d'essai et des distances d'isolement dans l'air.

ICS: 29.180-Transformers. Reactors
CTN: TC 14 - 1224

Standards Cancellations

Anula a IEC 60076-3:2000

Anula a IEC 60076-3:2000/COR1:2000

Modificaciones Normas

Es modificada por IEC 60076-3:2013/AMD1:2018

Otras Relaciones

Acuerdo de Frankfurt FprEN 60076-3:2013

The book in the author's words

Ultricies magna feugiat malesuada sociosqu varius vivamus cubilia parturient, himenaeos vitae vehicula nam placerat netus urna platea, nostra rutrum felis mattis penatibus velit quisque.

Button
Frequently Asked Questions Do you have any questions about our products?
  • Standards UNE, EN, ISO, IEC, BSI, DIN, ASTM, AFNOR, IEEE, SAE
  • In addition, you can request the rules of the rest of the organizations through the e-mail normas@aenor.com
  • Technical books on paper and in electronic format (PDF, epub).

The standards can be purchased in PDF, reading or paper. The reading standards are not download files, they can only be viewed in the client area. The standards ordered on paper and some of the books in the catalogue are printed on demand. 

Check deadlines in normas@aenor.com.

The license of use is for one user and one device, if you want to reproduce the content of the standard, you must request a license that will have an additional cost. Send us your inquiry here 

The AENOR standards and books that appear in the online store can only be purchased exclusively through the website. AENOR does not have a physical store.

Purchase procedure: by clicking on "Buy" the desired products will go to the shopping cart. If there are display problems, the recommended browser is Chrome.

To formalize the purchase you must access the customer area. If you are not registered as a customer, you must fill in a form with the data along with a password and username. This will create the account.

Once the "Customer data" form has been completed, "Order in progress" will be displayed with all the items loaded in the shopping cart, their prices, taxes established in current legislation and shipping costs if applicable.

The prices of the standards and books that appear in the various sections do not include taxes or shipping costs.

AENOR promotional codes consist of alphanumeric characters and can only be applied to online purchases, received through a specific offer and for a limited time. To apply your promotional code, you just have to enter it in step 2 of 4 of the purchase process on the website and click on "apply", after you have identified yourself and chosen the payment methods. Promo codes are not cumulative.

 

  • Credit or debit card (Visa, Mastercard) and PayPal.
  • Bank transfer. If you opt for this form of payment, you must first send AENOR a copy of the transfer by email to normas@aenor.com
  • The purchase invoice can be downloaded from the customer area, in my previous orders

In the case of clients of companies based abroad, the taxpayer identification number of the corresponding country (for example, in Argentina the CUIT), must be filled in the CIF/NIF - VAT field .

  • Direct download via the website in the Customer Area. In the customer area, which can only be accessed with a password and username, the products purchased will be available for a period of fifteen days from the date of purchase, as long as the payment has been accepted. Files in digital format are protected and in no case editable. Before purchasing them, it is important that the license of use is read and accepted as a prior step to purchase.
  • Shipping by courier. Products purchased on physical media are shipped by courier. The maximum delivery time in Spanish territory, from the acceptance of the order by AENOR, is:
  •  Approximately seven working days for all standards purchased through the store in paper format.
  • Approximately three days for books purchased through the store. Stocks of paper books are limited and their offer on the website does not imply availability within the indicated period. In the event that the requested book is not available, the customer is notified of the delay in receiving the order, which will be approximately seven working days. 

For the rest of the products that are not on the website, check availability and delivery time at normas@aenor.com.

1. For digital products (PDF, Epub), once delivery has been made by direct download via the website in the Customer Area, you will not have the right to exercise your right of withdrawal.

2. For personalised products on paper, once the purchase has been made, you will not have the right to exercise your right of withdrawal.

3.  For all other paper products, you have the right to withdraw from the sale within 14 calendar days from the date of purchase. Remember that for the return it is essential that the product is in perfect condition, sealed by the packaging and preserving its original packaging. The customer will be responsible for pickup and shipping costs.

The order invoice includes shipping costs, so there is no amount to pay to the courier. Shipping costs are calculated based on both the final destination of the order and the number of products ordered. They include transport and packaging costs. Shipping costs are subject to periodic revisions. Outlet books will have free shipping costs only if the shipment is made in the Peninsula.

Destination Up to three standards and/or publications From three standards and/or publications
Peninsula 7,31€ 8,60€
Balearic Islands 18,04€ 23,34€
Canary Islands, Ceuta and Melilla  18,04€ 23,34€
Europe 59,17€ 80,07€
United States and Canada 70,07€ 96,94€
Rest of the world 91,94€ 115,91€
  • Purchases made by residents of the Member States of the European Union will be subject to the payment of VAT (value added tax).
  • ​​
  • In the case of legal persons and natural persons who, acting as entrepreneurs, are domiciled in a Member State of the European Union (except residents in Spain) and have an intra-community NIF/VAT registered in the VIES census, they will be exempt from paying VAT, being an essential condition the sending of this document by email to normas@aenor.com.
  • Purchases made in a private capacity (natural person), regardless of where they have their residence, will be subject to the payment of VAT.
  • Purchases made by entities in non-EU countries will be exempt from paying VAT, as long as they send the corresponding tax residence document by email to normas@aenor.com.
  • The sale operations will be understood to have been carried out at AENOR's registered office: Génova 6, 28004, Madrid – Spain. 

The contract for the purchase of products through this Website shall be governed by Spanish law. Any dispute arising out of or in connection with the use of the Website or such contract shall be subject to the exclusive jurisdiction of the Courts and Tribunals of Madrid.

Notwithstanding the foregoing, if you are entering into this contract as a consumer under the terms of Royal Decree 1/2007, nothing in this clause shall affect the rights that may be granted to you as such under applicable law.