ASTM E83 - 16
Standard Practice for Verification and Classification of Extensometer Systems
| Aviso: | Las normas ASTM en lectura se visualizan a través del área decliente. Los archivos no se pueden descargar |
|---|---|
| Fecha edición: |
2016-12-15
Anulada
|
| Fecha cancelación: | 2016-12-15 |
| Idiomas disponibles: | Inglés |
| Resumen: | This practice covers procedures for the verification and classification of extensometer systems, but it is not intended to be a complete purchase specification. The practice is applicable only to instruments that indicate or record values that are proportional to changes in length corresponding to either tensile or compressive strain. Extensometer systems are classified on the basis of the magnitude of their errors. The apparatus for verifying extensometer systems shall provide a means for applying controlled displacements to a simulated specimen and for measuring these displacements accurately. Extensometer systems shall be classified in accordance with the requirements as to maximum error of strain indicated: Class A; Class B-1; Class B-2; Class C; Class D; and Class E. Extensometer systems shall be categorized in three types according to gage length: Type 1; Type 2; and Type 3. A verification procedure for extensometer systems shall be done in accordance with the specified requirements. |
| Scope: | 1.1 This practice covers procedures for the verification and classification of extensometer systems, but it is not intended to be a complete purchase specification. The practice is applicable only to instruments that indicate or record values that are proportional to changes in length corresponding to either tensile or compressive strain. Extensometer systems are classified on the basis of the magnitude of their errors. 1.2 Because strain is a dimensionless quantity, this document can be used for extensometers based on either SI or US customary units of displacement. Note 1: Bonded resistance strain gauges directly bonded to a specimen cannot be calibrated or verified with the apparatus described in this practice for the verification of extensometers having definite gauge points. (See procedures as described in Test Methods E251.) 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
| ICS: | 19.060 - Ensayos mecánicos |
| CTN: | E28.01 - E28.01 |
|
Otras Relaciones |
Es referenciada por F2977-20 Es referenciada por E2714-13R20 Es referenciada por E1012-19 Es referenciada por E0606_E0606M-21 Es referenciada por E0251-20A Es referenciada por D3039_D3039M-17 Es referenciada por D5083-17 Es referenciada por E0021-20 Es referenciada por D4535-21 Es referenciada por C1899-21 Es referenciada por E1922_E1922M-22 Es referenciada por E0238-17A Es referenciada por D4027-98R19 Es referenciada por E0209-18 Es referenciada por E2207-15R21 Es referenciada por E0132-17 Es referenciada por E2309_E2309M-20 Es referenciada por E2954-15R22 Es referenciada por C1819-21 Es referenciada por C1773-21 |