ASTM D92 - 11
Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester
| Fecha edición: |
2011-11-01
Anulada
|
|---|---|
| Fecha cancelación: | 2011-11-01 |
| Idiomas disponibles: | Inglés |
| Resumen: | |
| Keywords: | automated Cleveland open cup; Cleveland open cup; fire point open cup for flash point; flammability; flash point; petroleum products; Cleveland open cup test; Fire testing--petroleum products; Flash point--liquids; Open-cup flash point methods |
| Scope: | 1.1 This test method describes the determination of the flash point and fire point of petroleum products by a manual Cleveland open cup apparatus or an automated Cleveland open cup apparatus. Note 1—The precisions for fire point were not determined in the current interlaboratory program. Fire point is a parameter that is not commonly specified, although in some cases, knowledge of this flammability temperature may be desired. 1.2 This test method is applicable to all petroleum products with flash points above 79°C (175°F) and below 400°C (752°F) except fuel oils. Note 2—This test method may occasionally be specified for the determination of the fire point of a fuel oil. For the determination of the flash points of fuel oils, use Test Method D93. Test Method D93 should also be used when it is desired to determine the possible presence of small, but significant, concentrations of lower flash point substances that may escape detection by Test Method D92. Test Method D1310 can be employed if the flash point is known to be below 79°C (175°F). 1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.4 WARNING 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific warning statements, see 6.4, 7.1, 11.1.3, and 11.2.4. |
| ICS: | 75.080 - Productos petrolíferos en general, 13.220.40 - Comportamiento frente al fuego e inflamabilidad de materiales y productos |
| CTN: | D02.08 - D02.08 |
|
Otras Relaciones |
Es referenciada por F2161-21 Es referenciada por E0502-21A Es referenciada por D5964-16R21 Es referenciada por D3141_D3141M-21 Es referenciada por D4730-13R20 Es referenciada por A0849-15R21 Es referenciada por D2878-21 Es referenciada por D8254-19 Es referenciada por D4732-13R20 Es referenciada por D0471-16AR21 Es referenciada por D2225-20 Es referenciada por D4731-13R20 Es referenciada por D3143_D3143M-19 Es referenciada por D6871-17 Es referenciada por D0117-22 Es referenciada por F2417 - 24 Es referenciada por F2601 - 25 Es referenciada por D946/D946M - 25 Es referenciada por D4485 - 24 Es referenciada por D0449_D0449M-03R21 |