ASTM D6938 - 08a
Standard Test Method for In-Place Density and Water Content of Soil and Soil-Aggregate by Nuclear Methods (Shallow Depth)
| Aviso: | Las normas ASTM en lectura se visualizan a través del área decliente. Los archivos no se pueden descargar |
|---|---|
| Fecha edición: |
2008-06-01
Anulada
|
| Fecha cancelación: | 2008-06-01 |
| Idiomas disponibles: | Inglés |
| Resumen: | |
| Keywords: | Compaction test; acceptance testing; construction control; quality control; field density; in-place density; wet density; water content; dry density; nuclear methods, nuclear gauge; In-place density (of soil); Nuclear methods; Shallow depth test; Soil; Soil-aggregate; Water content |
| Scope: | 1.1 This test method describes the procedures for measuring in-place density and moisture of soil and soil-aggregate by use of nuclear equipment. The density of the material may be measured by direct transmission, backscatter, or backscatter/air-gap ratio methods. Measurements for water (moisture) content are taken at the surface in backscatter mode regardless of the mode being used for density. It is the intent of this subcommittee that this standard replace D 2922 and D 3017. 1.1.1 For limitations see Section 5 on Interferences. 1.2 The total or wet density of soil and soil-aggregate is measured by the attenuation of gamma radiation where, in direct transmission, the source is placed at a known depth up to 300 mm (12 in.) and the detector (s) remains on the surface (some gauges may reverse this orientation); or in backscatter or backscatter/air-gap the source and detector(s) both remain on the surface. 1.2.1 The density of the test sample in mass per unit volume is calculated by comparing the detected rate of gamma radiation with previously established calibration data. 1.2.2 The dry density of the test sample is obtained by subtracting the water mass per unit volume from the test sample wet density (Section 11). Most gauges display this value directly. 1.3 The gauge is calibrated to read the water mass per unit volume of soil or soil-aggregate. When divided by the density of water and then multiplied by 100, the water mass per unit volume is equivalent to the volumetric water content. The water mass per unit volume is determined by the thermalizing or slowing of fast neutrons by hydrogen, a component of water. The neutron source and the thermal neutron detector are both located at the surface of the material being tested. The water content most prevalent in engineering and construction activities is known as the gravimetric water content, w, and is the ratio of the mass of the water in pore spaces to the total mass of solids, expressed as a percentage. 1.4 Two alternative procedures are provided. 1.4.1 Procedure A describes the direct transmission method in which the gamma source rod extends through the base of the gauge into a pre-formed hole to a desired depth. The direct transmission is the preferred method. 1.4.2 Procedure B involves the use of a dedicated backscatter gauge or the source rod in the backscatter position. This places the gamma and neutron sources and the detectors in the same plane. 1.5 SI Units—The values stated in SI units are to be regarded as the standard. The values in inch-pound units (ft – lb units) are provided for information only. 1.6 All observed and calculated values shall conform to the guide for significant digits and rounding established in Practice D 6026 1.6.1 The procedures used to specify how data are collected, recorded, and calculated in this standard are regarded as the industry standard. In addition, they are representative of the significant digits that should generally be retained. The procedures used do not consider material variation, purpose for obtaining the data, special purpose studies, or any considerations for the user’s objectives; and it is common practice to increase or reduce significant digits of reported data to be commensurate with these considerations. It is beyond the scope of this standard to consider significant digits used in analysis methods for engineering design. 1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
| ICS: | 13.080.20 - Propiedades físicas de los suelos |
| CTN: | D18.08 - D18.08 |
|
Otras Relaciones |
Es referenciada por D8152-18 Es referenciada por B0790_B0790M-16R21 Es referenciada por B0788_B0788M-09R20 Es referenciada por F1668-16R22 Es referenciada por D7380_D7380M-21 Es referenciada por A0807_A0807M-19 Es referenciada por D5220_D5220M-21 Es referenciada por D5080-20 Es referenciada por B0789_B0789M-16R21 Es referenciada por D5195-21 Es referenciada por D7759_D7759M-21 Es referenciada por D7765-18A Es referenciada por D8297/D8297M - 23 Es referenciada por E2060-22 Es referenciada por D8153-22 Es referenciada por D8167_D8167M-23E01 Es referenciada por A0798_A0798M-22 Es referenciada por F2656/F2656M - 23 Es referenciada por D3839 - 25 Es referenciada por D7013/D7013M - 24 |