BS EN 50549-1:2019
Requirements for generating plants to be connected in parallel with distribution networks. Connection to a LV distribution network. Generating plants up to and including Type B
| Fecha edición: |
2025-01-29
Anulada
|
|---|---|
| Fecha cancelación: | 2025-01-29 |
| Idiomas disponibles: | Inglés |
| Resumen: | This document specifies the technical requirements for the protection functions and the operational capabilities for generating plants, intended to operate in parallel with LV distribution networks. For practical reasons this document refers to the responsible party where requirements have to be defined by an actor other than the DSO e.g. TSO, member state, regulatory authorities according to the legal framework. Typically the DSO will inform the producer about these requirements.
The requirements of this European Standard apply, irrespective of the kind of energy source and irrespective of the presence of loads in the producer’s network, to generating plants, generating modules, electrical machinery and electronic equipment that meet all of the following conditions:
If generating modules of different type (A or B) are combined in one plant, different requirements apply for the different modules based on the type of each module. EXAMPLE: If a generating plant consists of multiple generating modules (see 3.2.1), according to COMMISSION REGLUATION (EU) 2016/631 the situation might occur, that some generating modules are of type A and some are of type B. Unless specified otherwise by the DSO and the responsible party, generating plants connected to a medium voltage distribution network with a maximum apparent power up to 150 kVA can comply with this European Standard as alternative to the requirements of EN 50549-2. A different threshold may be defined by the DSO and the responsible party. This document recognizes the existence of specific technical requirements (e.g. grid codes) of the DSO or another responsible party within a member state and these must be complied with. Excluded from the scope are:
|
| ICS: | |
| CTN: | GEL/8 - GEL/8 |
|
Equivalencia Internacional |
Idéntica EN 50549-1:2019/AC:2019-04 |
|
Reemplazo Normas |
Reemplaza a BS EN 50438:2013 Es reemplazada por BS EN 50549-1:2019+A1:2023 |