BS EN 50121-5:2017+A1:2019
Railway applications. Electromagnetic compatibility. Emission and immunity of fixed power supply installations and apparatus
| Fecha edición: |
2019-05-02
En Vigor
|
|---|---|
| Idiomas disponibles: | Inglés |
| Resumen: | This European Standard applies to emission and immunity aspects of EMC for electrical and electronic apparatus and systems intended for use in railway fixed installations for power supply. This includes the power feed to the apparatus, the apparatus itself with its protective control circuits, trackside items such as switching stations, power autotransformers, booster transformers, substation power switchgear and power switchgear to other longitudinal and local supplies. Filters operating at railway system voltage (for example, for harmonic suppression or power factor correction) are not included in this standard since each site has special requirements. Filters would normally have separate enclosures with separate rules for access. If electromagnetic limits are required, these will appear in the specification for the equipment. If a port is intended to transmit or receive for the purpose of radio communication (intentional radiators, e.g. transponder systems), then the radiated emission requirement in this standard are not intended to be applicable to the intentional transmission from a radio-transmitter as defined by the ITU. The frequency range considered is from DC to 400 GHz. No measurements need to be performed at frequencies where no requirement is specified. Emission and immunity limits are given for items of apparatus which are situated:
The immunity levels given in this standard apply for:
Apparatus and systems which are in an environment which can be described as residential, commercial or light industry, even when placed within the physical boundary of the railway substation, shall comply with EN 61000‑6‑1:2007 for immunity and EN 61000‑6‑3:2007 for emission requirements. Excluded from the immunity requirements of this standard is power supply apparatus which is intrinsically immune to the tests defined in Tables 1 to 6. NOTE An example is an 18 MVA 230 kV to 25 kV power supply transformer. These specific provisions are to be used in conjunction with the general provisions in EN 50121‑1 . This part of the standard covers requirements for both apparatus and fixed installations. The sections for fixed installations are not relevant for CE marking. |
| ICS: | |
| CTN: | GEL/9 - GEL/9 |
|
Equivalencia Internacional |
Idéntica EN 50121-5:2017/A1:2019 |
|
Reemplazo Normas |
Reemplaza a BS EN 50121-5:2015 |