ASTM E1086 - 14
Standard Test Method for Analysis of Austenitic Stainless Steel by Spark Atomic Emission Spectrometry
| Aviso: | Las normas ASTM en lectura se visualizan a través del área decliente. Los archivos no se pueden descargar | ||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Fecha edición: |
2014-03-01
Anulada
|
||||||||||||||||||||
| Fecha cancelación: | 2014-03-01 | ||||||||||||||||||||
| Idiomas disponibles: | Inglés | ||||||||||||||||||||
| Resumen: | |||||||||||||||||||||
| Keywords: | austenitic stainless steel; spark atomic emission; spectrometric analysis; spectrometry | ||||||||||||||||||||
| Scope: | 1.1 This test method2 covers the analysis of austenitic stainless steel by spark atomic emission vacuum spectrometry for the following elements in the ranges shown
1.2 This test method is designed for the routine analysis of chill-cast disks or inspection testing of stainless steel samples that have a flat surface of at least 13 mm (0.5 in.) in diameter. The samples must be sufficiently massive to prevent overheating during the discharge and of a similar metallurgical condition and composition as the reference materials. 1.3 One or more of the reference materials must closely approximate the composition of the specimen. The technique of analyzing reference materials with unknowns and performing the indicated mathematical corrections may also be used to correct for interference effects and to compensate for errors resulting from instrument drift. A variety of such systems are commonly used. Any of these that will achieve analytical accuracy equivalent to that reported for this test method are acceptable. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||||||
| ICS: | 77.140.20 - Aceros inoxidables, 77.040.30 - Análisis químico de metales | ||||||||||||||||||||
| CTN: | E01.01 - E01.01 | ||||||||||||||||||||
|
Anulaciones Normas |
Anula a E1086-08 |
||||||||||||||||||||
|
Otras Relaciones |
Es referenciada por A0751-21 Es referenciada por E2972-15R19 Es referenciada por F3184 - 16(2023) Es referenciada por B883 - 24 Es referenciada por B0853-16R21E01 |