-50% discount* If you buy the same UNE standard in different languages. * Discount on the lower pvp.

ASTM E1457 - 23e1

Standard Test Method for Measurement of Creep Crack Growth Times in Metals

Warning: ASTM standards for reading are viewed through the client area. Thefilescannot be downloaded.
Edition date: 2023-11-15
In Force
Available languages: English
Summary:

Scope:

1.1 This test method covers the determination of creep crack initiation (CCI) and creep crack growth (CCG) in metals at elevated temperatures using pre-cracked specimens subjected to static or quasi-static loading conditions. The solutions presented in this test method are validated for base material (that is, homogenous properties) and mixed base/weld material with inhomogeneous microstructures and creep properties. The CCI time, t0.2, which is the time required to reach an initial crack extension of δai = 0.2 mm to occur from the onset of first applied force, and CCG rate, a˙ or da/dt are expressed in terms of the magnitude of creep crack growth correlated by fracture mechanics parameters, C* or K, with C* defined as the steady state determination of the crack tip stresses derived in principal from C*(t) and Ct (1-17).2 The crack growth derived in this manner is identified as a material property which can be used in modeling and life assessment methods (17-28).

1.1.1 The choice of the crack growth correlating parameter C*, C*(t), Ct, or K depends on the material creep properties, geometry and size of the specimen. Two types of material behavior are generally observed during creep crack growth tests; creep-ductile (1-17) and creep-brittle (29-44). In creep ductile materials, where creep strains dominate and creep crack growth is accompanied by substantial time-dependent creep strains at the crack tip, the crack growth rate is correlated by the steady state definitions of Ct or C*(t) , defined as C* (see 1.1.4). In creep-brittle materials, creep crack growth occurs at low creep ductility. Consequently, the time-dependent creep strains are comparable to or dominated by accompanying elastic strains local to the crack tip. Under such steady state creep-brittle conditions, Ct or K could be chosen as the correlating parameter (8-14).

1.1.2 In any one test, two regions of crack growth behavior may be present (12, 13). The initial transient region where elastic strains dominate and creep damage develops and in the steady state region where crack grows proportionally to time. Steady-state creep crack growth rate behavior is covered by this standard. In addition, specific recommendations are made in 11.7 as to how the transient region should be treated in terms of an initial crack growth period. During steady state, a unique correlation exists between da/dt and the appropriate crack growth rate relating parameter.

1.1.3 In creep ductile materials, extensive creep occurs when the entire un-cracked ligament undergoes creep deformation. Such conditions are distinct from the conditions of small-scale creep and transition creep (1-10). In the case of extensive creep, the region dominated by creep deformation is significant in size in comparison to both the crack length and the uncracked ligament sizes. In small-scale-creep only a small region of the un-cracked ligament local to the crack tip experiences creep deformation.

1.1.4 The creep crack growth rate in the extensive creep region is correlated by the C*(t)-integral. The Ct parameter correlates the creep crack growth rate in the small-scale creep and the transition creep regions and reduces, by definition, to C*(t) in the extensive creep region (5). Hence in this document the definition C* is used as the relevant parameter in the steady state extensive creep regime whereas C*(t) and/or Ct are the parameters which describe the instantaneous stress state from the small scale creep, transient and the steady state regimes in creep. The recommended functions to derive C* for the different geometries shown in Annex A1 is described in Annex A2.

1.1.5 An engineering definition of an initial crack extension size δai is used in order to quantify the initial period of crack development. This distance is given as 0.2 mm. It has been shown (41-44) that this initial period which exists at the start of the test could be a substantial period of the test time. During this early period the crack tip undergoes damage development as well as redistribution of stresses prior reaching steady state. Recommendation is made to correlate this initial crack growth period defined as t0.2 at δai = 0.2 mm with the steady state C* when the crack tip is under extensive creep and with K for creep brittle conditions. The values for C* and K should be calculated at the final specified crack size defined as ao + δai where ao is initial size of the starter crack.

1.1.6 The recommended specimens for CCI and CCG testing is the standard compact tension specimen C(T) (see Fig. A1.1) which is pin-loaded in tension under constant loading conditions. The clevis setup is shown in Fig. A1.2 (see 7.2.1 for details). Additional geometries which are valid for testing in this procedure are shown in Fig. A1.3. These are the C-ring in tension CS(T), middle crack specimen in tension M(T), single edge notched tension SEN(T), single edge notched bend SEN(B), and double edge notched tension DEN(T). In Fig. A1.3, the specimens’ side-grooving-position for measuring displacement at the force-line displacement (FLD) and crack mouth opening displacement (CMOD) and positions for the electric potential drop (EPD) input and output leads are shown. Recommended loading for the tension specimens is pin-loading. The configurations, size range are given in Table A1.1 of Annex A1, (43-47). Specimen selection will be discussed in 5.9.

1.1.7 The state-of-stress at the crack tip may have an influence on the creep crack growth behavior and can cause crack-front tunneling in plane-sided specimens. Specimen size, geometry, crack length, test duration and creep properties will affect the state-of-stress at the crack tip and are important factors in determining crack growth rate. A recommended size range of test specimens and their side-grooving are given in Table A1.1 in Annex A1. It has been shown that for this range the cracking rates do not vary for a range of materials and loading conditions (43-47). Suggesting that the level of constraint, for the relatively short term test durations (less than one year), does not vary within the range of normal data scatter observed in tests of these geometries. However, it is recommended that, within the limitations imposed on the laboratory, that tests are performed on different geometries, specimen size, dimensions and crack size starters. In all cases a comparison of the data from the above should be made by testing the standard C(T) specimen where possible. It is clear that increased confidence in the materials crack growth data can be produced by testing a wider range of specimen types and conditions as described above.

1.1.8 Material inhomogeneity, residual stresses and material degradation at temperature, specimen geometry and low-force long duration tests (mainly greater that one year) can influence the rate of crack initiation and growth properties (42-50). In cases where residual stresses exist, the effect can be significant when test specimens are taken from material that characteristically embodies residual stress fields or the damaged material, or both. For example, weldments, or thick cast, forged, extruded, components, plastically bent components and complex component shapes, or a combination thereof, where full stress relief is impractical. Specimens taken from such component that contain residual stresses may likewise contain residual stresses which may have altered in their extent and distribution due to specimen fabrication. Extraction of specimens in itself partially relieves and redistributes the residual stress pattern; however, the remaining magnitude could still cause significant effects in the ensuing test unless post-weld heat treatment (PWHT) is performed. Otherwise residual stresses are superimposed on applied stress and results in crack-tip stress intensity that is different from that based solely on externally applied forces or displacements. Not taking the tensile residual stress effect into account will produce C* values lower than expected effectively producing a faster cracking rate with respect to a constant C*. This would produce conservative estimates for life assessment and non-conservative calculations for design purposes. It should also be noted that distortion during specimen machining can also indicate the presence of residual stresses.

1.1.9 Stress relaxation of the residual stresses due to creep and crack extension should also be taken into consideration. No specific allowance is included in this standard for dealing with these variations. However the method of calculating C* presented in this document which used the specimen’s creep displacement rate to estimate C* inherently takes into account the effects described above as reflected by the instantaneous creep strains that have been measured. However extra caution should still be observed with the analysis of these types of tests as the correlating parameters K and C* shown in Annex A2 even though it is expected that stress relaxation at high temperatures could in part negate the effects due to residual stresses. Annex A4 presents the correct calculations needed to derive J and C* for weldment tests where a mismatch factor needs to be taken into account.

1.1.10 Specimen configurations and sizes other than those listed in Table A1.1 which are tested under constant force will involve further validity requirements. This is done by comparing data from recommended test configurations. Nevertheless, use of other geometries are applicable by this method provided data are compared to data obtained from standard specimens (as identified in Table A1.1) and the appropriate correlating parameters have been validated.

1.2 The values stated in SI units are to be regarded as standard. The values given in parentheses after SI units are provided for information only and are not considered standard.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

ICS: 77.040.10-Mechanical testing of metals
CTN: E08.06 - E08.06

Standards Cancellations

Anula a E1457-23

Otras Relaciones

Es referenciada por E1823 - 24c

Es referenciada por E2760 - 19e3

The book in the author's words

Ultricies magna feugiat malesuada sociosqu varius vivamus cubilia parturient, himenaeos vitae vehicula nam placerat netus urna platea, nostra rutrum felis mattis penatibus velit quisque.

Button
Frequently Asked Questions Do you have any questions about our products?
  • Standards UNE, EN, ISO, IEC, BSI, DIN, ASTM, AFNOR, IEEE, SAE
  • In addition, you can request the rules of the rest of the organizations through the e-mail normas@aenor.com
  • Technical books on paper and in electronic format (PDF, epub).

The standards can be purchased in PDF, reading or paper. The reading standards are not download files, they can only be viewed in the client area. The standards ordered on paper and some of the books in the catalogue are printed on demand. 

Check deadlines in normas@aenor.com.

The license of use is for one user and one device, if you want to reproduce the content of the standard, you must request a license that will have an additional cost. Send us your inquiry here 

The AENOR standards and books that appear in the online store can only be purchased exclusively through the website. AENOR does not have a physical store.

Purchase procedure: by clicking on "Buy" the desired products will go to the shopping cart. If there are display problems, the recommended browser is Chrome.

To formalize the purchase you must access the customer area. If you are not registered as a customer, you must fill in a form with the data along with a password and username. This will create the account.

Once the "Customer data" form has been completed, "Order in progress" will be displayed with all the items loaded in the shopping cart, their prices, taxes established in current legislation and shipping costs if applicable.

The prices of the standards and books that appear in the various sections do not include taxes or shipping costs.

AENOR promotional codes consist of alphanumeric characters and can only be applied to online purchases, received through a specific offer and for a limited time. To apply your promotional code, you just have to enter it in step 2 of 4 of the purchase process on the website and click on "apply", after you have identified yourself and chosen the payment methods. Promo codes are not cumulative.

 

  • Credit or debit card (Visa, Mastercard) and PayPal.
  • Bank transfer. If you opt for this form of payment, you must first send AENOR a copy of the transfer by email to normas@aenor.com
  • The purchase invoice can be downloaded from the customer area, in my previous orders

In the case of clients of companies based abroad, the taxpayer identification number of the corresponding country (for example, in Argentina the CUIT), must be filled in the CIF/NIF - VAT field .

  • Direct download via the website in the Customer Area. In the customer area, which can only be accessed with a password and username, the products purchased will be available for a period of fifteen days from the date of purchase, as long as the payment has been accepted. Files in digital format are protected and in no case editable. Before purchasing them, it is important that the license of use is read and accepted as a prior step to purchase.
  • Shipping by courier. Products purchased on physical media are shipped by courier. The maximum delivery time in Spanish territory, from the acceptance of the order by AENOR, is:
  •  Approximately seven working days for all standards purchased through the store in paper format.
  • Approximately three days for books purchased through the store. Stocks of paper books are limited and their offer on the website does not imply availability within the indicated period. In the event that the requested book is not available, the customer is notified of the delay in receiving the order, which will be approximately seven working days. 

For the rest of the products that are not on the website, check availability and delivery time at normas@aenor.com.

1. For digital products (PDF, Epub), once delivery has been made by direct download via the website in the Customer Area, you will not have the right to exercise your right of withdrawal.

2. For personalised products on paper, once the purchase has been made, you will not have the right to exercise your right of withdrawal.

3.  For all other paper products, you have the right to withdraw from the sale within 14 calendar days from the date of purchase. Remember that for the return it is essential that the product is in perfect condition, sealed by the packaging and preserving its original packaging. The customer will be responsible for pickup and shipping costs.

The order invoice includes shipping costs, so there is no amount to pay to the courier. Shipping costs are calculated based on both the final destination of the order and the number of products ordered. They include transport and packaging costs. Shipping costs are subject to periodic revisions. Outlet books will have free shipping costs only if the shipment is made in the Peninsula.

Destination Up to three standards and/or publications From three standards and/or publications
Peninsula 7,31€ 8,60€
Balearic Islands 18,04€ 23,34€
Canary Islands, Ceuta and Melilla  18,04€ 23,34€
Europe 59,17€ 80,07€
United States and Canada 70,07€ 96,94€
Rest of the world 91,94€ 115,91€
  • Purchases made by residents of the Member States of the European Union will be subject to the payment of VAT (value added tax).
  • ​​
  • In the case of legal persons and natural persons who, acting as entrepreneurs, are domiciled in a Member State of the European Union (except residents in Spain) and have an intra-community NIF/VAT registered in the VIES census, they will be exempt from paying VAT, being an essential condition the sending of this document by email to normas@aenor.com.
  • Purchases made in a private capacity (natural person), regardless of where they have their residence, will be subject to the payment of VAT.
  • Purchases made by entities in non-EU countries will be exempt from paying VAT, as long as they send the corresponding tax residence document by email to normas@aenor.com.
  • The sale operations will be understood to have been carried out at AENOR's registered office: Génova 6, 28004, Madrid – Spain. 

The contract for the purchase of products through this Website shall be governed by Spanish law. Any dispute arising out of or in connection with the use of the Website or such contract shall be subject to the exclusive jurisdiction of the Courts and Tribunals of Madrid.

Notwithstanding the foregoing, if you are entering into this contract as a consumer under the terms of Royal Decree 1/2007, nothing in this clause shall affect the rights that may be granted to you as such under applicable law.