Summary:

Scope:

1.1 This practice describes procedures and methodologies based on the statistical principles of Practice D6708 to validate whether the degree of agreement between the results produced by a total analyzer system (or its subsystem), versus the results produced by an independent test method that purports to measure the same property, meets user-specified requirements. This is a performance-based validation, to be conducted using a set of materials that are not used a priori in the development of any correlation between the two measurement systems under investigation. A result from the independent test method is herein referred to as a Primary Test Method Result (PTMR).

1.1.1 The degree of agreement described in 1.1 can be either for PPTMRs and PTMRs measured on the same materials, or for PPTMRs measured on basestocks and PTMRs measured on these same basestocks after constant level additivation.

1.1.2 In some cases, a two-step procedure is employed. In the first step, the analyzer and PTM are applied to the measurement of the same blendstock material. If the analyzer employed in Step 1 is a multivariate spectrophotometric analyzer, then Practice D6122 is used to access the agreement between the PPTMRs and the PTMRs for this first step. Otherwise, this practice is used to compare the PPTMRs to the PTMRs measured for this blendstock to determine the degree of agreement. In a second step, the PPTMRs produced in Step 1 are used as inputs to a second model that predicts the results obtained when the PTM is applied to the analysis of the finished blended product. Since this second step does not use analyzer readings, the validation of the second step is done independently. Step 2 is only performed on valid Step 1 results. Note that the second model might accommodate variable levels or multiple material additions to the blendstock.

1.2 This practice assumes any correlation necessary to mitigate systemic biases between the analyzer system and PTM have been applied to the analyzer results. See Guide D7235 for procedures for establishing such correlations.

1.3 This practice assumes any modeling techniques employed have the necessary tuning to mitigate systemic biases between the analyzer PPTMR and PTMR have been applied to the model results. Model form and tuning is not covered by this practice, only the validation of the model output.

1.4 This practice requires that both the primary method against which the analyzer is compared to, and the analyzer system under investigation, are in statistical control. Practices described in Practice D6299 should be used to ensure this condition is met.

1.5 This practice applies if the process stream analyzer system and the primary test method are based on the same measurement principle(s), or, if the process stream analyzer system uses a direct and well-understood measurement principle that is similar to the measurement principle of the primary test method. This practice also applies if the process stream analyzer system uses a different measurement technology from the primary test method, provided that the calibration protocol for the direct output of the analyzer does not require use of the PTMRs (see Case 1 in Note 1).

1.6 This practice does not apply if the process stream analyzer system utilizes an indirect or mathematically modeled measurement principle such as chemometric or multivariate analysis techniques where PTMRs are required for the chemometric or multivariate model development. Users should refer to Practice D6122 for detailed validation procedures for these types of analyzer systems (see Case 2 in Note 1).

Note 1: For example, for the measurement of benzene in spark ignition fuels, comparison of a Mid-Infrared process analyzer system based on Test Method D6277 to a Test Method D3606 gas chromatography primary test method would be considered Case 1, and this practice would apply. For each sample, the Mid-Infrared spectrum is converted into a single analyzer result using methodology (Test Method D6277) that is independent of the primary test method (Test Method D3606). However, when the same analyzer uses a multivariate model to correlate the measured Mid-Infrared spectrum to Test Method D3606 reference values using the methodology of Practice D8321, it is considered Case 2 and Practice D6122 applies. In this case 2 example, the direct output of the analyzer is the spectrum, and the conversion of this multivariate output to an analyzer result require use of Practice D6122, hence it is not independent of the primary test method.

1.7 Performance Validation is conducted by calculating the precision and bias of the differences between results from the analyzer system (or subsystem) after the application of any necessary correlation, (such results are herein referred to as Predicted Primary Test Method Results (PPTMRs)), versus the PTMRs for the same sample set. Results used in the calculation are for samples that are not used in the development of the correlation. The calculated precision and bias are statistically compared to user-specified requirements for the analyzer system application.

1.7.1 For analyzers used in product release or product quality certification applications, the precision and bias requirement for the degree of agreement are typically based on the site or published precision of the Primary Test Method.

Note 2: In most applications of this type, the PTM is the specification-cited test method.

1.7.2 This practice does not describe procedures for establishing precision and bias requirements for analyzer system applications. Such requirements must be based on the criticality of the results to the intended business application and on contractual and regulatory requirements. The user must establish precision and bias requirements prior to initiating the validation procedures described herein.

1.8 Two procedures for validation are described: the line sample procedure and the validation reference material (VRM) injection procedure.

1.9 Only the analyzer system or subsystem downstream of the VRM injection point or the line sample extraction point is being validated by this practice.

1.10 The line sample procedure is limited to applications where material can be safely withdrawn from the sampling point of the analyzer unit without significantly altering the property of interest.

1.10.1 The line sample procedure is the primary option for when the validation is for (2b) materials including effect from additional treatment to the material.

1.11 Validation information obtained in the application of this practice is applicable only to the type and property range of the materials used to perform the validation.

1.12 Two types of validation are described: General Validation, and Level Specific Validation. These are typically conducted at installation or after major maintenance once the system mechanical fitness-for-use has been established.

1.12.1 General Validation is based on the statistical principles and methodology of Practice D6708. In most cases, General Validation is preferred, but may not always be possible if the variation in validation materials is insufficient. General Validation will validate analyzer operation over a wider operating range than Level Specific Validation.

1.12.2 When the variation in available validation materials is insufficient to satisfy the requirements of Practice D6708, a Level Specific Validation is done to validate analyzer operation over a limited range.

1.12.3 The validation outcome are considered valid only within the range covered by the validation material Data from several different Validations (general or level-specific) can potentially be combined for use in a General Validation.

1.13 Procedures for the continual validation of system performance are described. These procedures are typically applied at a frequency commensurate with the criticality of the application.

1.14 This practice does not address procedures for diagnosing causes of validation failure.

1.15 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.16 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

ICS: 17.120.10-Flow in closed conduits
CTN: D02.25 - D02.25

Standards Cancellations

Anula a D3764-22

Otras Relaciones

Es referenciada por D7314-21

Es referenciada por D7166-23

Es referenciada por D7278-21

Es referenciada por D8321-22

Es referenciada por E2898-20A

Es referenciada por D7453-22

Es referenciada por D8340-22

Es referenciada por D6624-20

Es referenciada por D7808-22

Es referenciada por D7235-21A

Es referenciada por D6299 - 25a

Es referenciada por D7825 - 24

Es referenciada por D6122 - 23

Es referenciada por D6621-21

Es referenciada por D7165-22

Es referenciada por D8455-22

Es referenciada por D7164-21

The book in the author's words

Ultricies magna feugiat malesuada sociosqu varius vivamus cubilia parturient, himenaeos vitae vehicula nam placerat netus urna platea, nostra rutrum felis mattis penatibus velit quisque.

Button
Frequently Asked Questions Do you have any questions about our products?
  • Standards UNE, EN, ISO, IEC, BSI, DIN, ASTM, AFNOR, IEEE, SAE
  • In addition, you can request the rules of the rest of the organizations through the e-mail normas@aenor.com
  • Technical books on paper and in electronic format (PDF, epub).

The standards can be purchased in PDF, reading or paper. The reading standards are not download files, they can only be viewed in the client area. The standards ordered on paper and some of the books in the catalogue are printed on demand. 

Check deadlines in normas@aenor.com.

The license of use is for one user and one device, if you want to reproduce the content of the standard, you must request a license that will have an additional cost. Send us your inquiry here 

The AENOR standards and books that appear in the online store can only be purchased exclusively through the website. AENOR does not have a physical store.

Purchase procedure: by clicking on "Buy" the desired products will go to the shopping cart. If there are display problems, the recommended browser is Chrome.

To formalize the purchase you must access the customer area. If you are not registered as a customer, you must fill in a form with the data along with a password and username. This will create the account.

Once the "Customer data" form has been completed, "Order in progress" will be displayed with all the items loaded in the shopping cart, their prices, taxes established in current legislation and shipping costs if applicable.

The prices of the standards and books that appear in the various sections do not include taxes or shipping costs.

AENOR promotional codes consist of alphanumeric characters and can only be applied to online purchases, received through a specific offer and for a limited time. To apply your promotional code, you just have to enter it in step 2 of 4 of the purchase process on the website and click on "apply", after you have identified yourself and chosen the payment methods. Promo codes are not cumulative.

 

  • Credit or debit card (Visa, Mastercard) and PayPal.
  • Bank transfer. If you opt for this form of payment, you must first send AENOR a copy of the transfer by email to normas@aenor.com
  • The purchase invoice can be downloaded from the customer area, in my previous orders

In the case of clients of companies based abroad, the taxpayer identification number of the corresponding country (for example, in Argentina the CUIT), must be filled in the CIF/NIF - VAT field .

  • Direct download via the website in the Customer Area. In the customer area, which can only be accessed with a password and username, the products purchased will be available for a period of fifteen days from the date of purchase, as long as the payment has been accepted. Files in digital format are protected and in no case editable. Before purchasing them, it is important that the license of use is read and accepted as a prior step to purchase.
  • Shipping by courier. Products purchased on physical media are shipped by courier. The maximum delivery time in Spanish territory, from the acceptance of the order by AENOR, is:
  •  Approximately seven working days for all standards purchased through the store in paper format.
  • Approximately three days for books purchased through the store. Stocks of paper books are limited and their offer on the website does not imply availability within the indicated period. In the event that the requested book is not available, the customer is notified of the delay in receiving the order, which will be approximately seven working days. 

For the rest of the products that are not on the website, check availability and delivery time at normas@aenor.com.

1. For digital products (PDF, Epub), once delivery has been made by direct download via the website in the Customer Area, you will not have the right to exercise your right of withdrawal.

2. For personalised products on paper, once the purchase has been made, you will not have the right to exercise your right of withdrawal.

3.  For all other paper products, you have the right to withdraw from the sale within 14 calendar days from the date of purchase. Remember that for the return it is essential that the product is in perfect condition, sealed by the packaging and preserving its original packaging. The customer will be responsible for pickup and shipping costs.

The order invoice includes shipping costs, so there is no amount to pay to the courier. Shipping costs are calculated based on both the final destination of the order and the number of products ordered. They include transport and packaging costs. Shipping costs are subject to periodic revisions. Outlet books will have free shipping costs only if the shipment is made in the Peninsula.

Destination Up to three standards and/or publications From three standards and/or publications
Peninsula 7,31€ 8,60€
Balearic Islands 18,04€ 23,34€
Canary Islands, Ceuta and Melilla  18,04€ 23,34€
Europe 59,17€ 80,07€
United States and Canada 70,07€ 96,94€
Rest of the world 91,94€ 115,91€
  • Purchases made by residents of the Member States of the European Union will be subject to the payment of VAT (value added tax).
  • ​​
  • In the case of legal persons and natural persons who, acting as entrepreneurs, are domiciled in a Member State of the European Union (except residents in Spain) and have an intra-community NIF/VAT registered in the VIES census, they will be exempt from paying VAT, being an essential condition the sending of this document by email to normas@aenor.com.
  • Purchases made in a private capacity (natural person), regardless of where they have their residence, will be subject to the payment of VAT.
  • Purchases made by entities in non-EU countries will be exempt from paying VAT, as long as they send the corresponding tax residence document by email to normas@aenor.com.
  • The sale operations will be understood to have been carried out at AENOR's registered office: Génova 6, 28004, Madrid – Spain. 

The contract for the purchase of products through this Website shall be governed by Spanish law. Any dispute arising out of or in connection with the use of the Website or such contract shall be subject to the exclusive jurisdiction of the Courts and Tribunals of Madrid.

Notwithstanding the foregoing, if you are entering into this contract as a consumer under the terms of Royal Decree 1/2007, nothing in this clause shall affect the rights that may be granted to you as such under applicable law.